Skip to main navigation Skip to search Skip to main content

Transverse Beam Position Monitor Prototype Utilising Incoherent Cherenkov Diffraction Radiation

Research output: Thesis › Doctoral Thesis

36 Downloads (Pure)

Abstract

Cherenkov Diffraction Radiation (ChDR) is a phenomenon that has is actively being investigated at different research institutions across a multitude of countries. ChDR has been shown to have a wide array of applications in accelerator diagnostics from beam size to beam position measurements. The nature of ChDR allows it to be usable in and around dipole magnets, which some other forms of Beam Position Monitors (BPMs) do not have. The work presented in this thesis outlines the development and testing of a one-dimensional BPM prototype utilising incoherent ChDR, and a data transfer system comprised of optical fibres. Theoretical ChDR simulations are shown, including the affect on emission angle and photon yield when altering different beam and target parameters. Simulations are included displaying the expected emission cone when considering only horizontal or vertical components of the electron field of the electron beam. The prototype assembly is comprised of two fused silica prisms coupled to an optical fibre array via Ultra High Vacuum (UHV) fibre collimators. The assembly can be split such that only one prism is inside the accelerator and exposed to the electron beam. The fundamental ChDR properties of the single prism assembly are explored, these being: the intensity dependence on impact parameter; the intensity dependence on rotation angle of the prism and; intensity dependence on the vertical position of the prism. Impact parameter data is acquired via an existing Inductive Beam Position Monitor (IBPM) Upon addition of the second prism the beam position capabilities of the ChDR prototype are explored for 500, 650 and 800~nm emission with the IBPM as a reference BPM. The results show that not only is an incoherent ChDR test bed utilising an optical fibre network possible but beam position measurements are also possible with a maximum operational range witnessed at 800~nm of $\sim 3$~mm.
Original languageEnglish
QualificationPh.D.
Awarding Institution
  • Royal Holloway, University of London
Supervisors/Advisors
  • Karataev, Pavel, Supervisor
  • Bobb, Lorraine, Supervisor, External person
Award date1 Mar 2026
Publication statusUnpublished - 2026

Keywords

  • Accelerator Physics
  • Accelerator Diagnostics
  • Cherenkov Diffraction Radiation
  • Polarisation Radiation
  • Beam Position Monitor
  • Diamond Light Source
  • ChDR
  • BPM
  • Prototype

Cite this