Detector parametrisation for the front end test stand laserwire diagnostic using GEANT4

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Comprehensive simulations for the FETS laserwire have been made with the developed Geant4 laser package. Feasibility of the longitudinal mode laser to provide full 6D beam characterisation has been made. Simulation results have been used to outline minimum detector requirements. The detector necessary for measuring the 6D phase space requires a drift distance of at least 2.5m between interaction point and detection plane, a 1mm2 spatial resolution, across a total transverse area of 40mm2 for the transverse measurements. To include longitudinal data the time resolution of the detector would need to be 200ps or less. The Timepix4 is proposed as a candidate detector due to its tile structure enabling custom size detector, a < 100 μm spacial resolution, and a 195 ps time resolution.
Original languageEnglish
Title of host publication14th International Particle Accelerator Conference
Subtitle of host publication07-12 May 2023
Place of PublicationVenice, Italy
PublisherJACoW Publishing
Pages4843-4846
Number of pages4
ISBN (Electronic)978-3-95450-231-8
DOIs
Publication statusPublished - 26 Sept 2023